Domů » NOBASIL FKD

NOBASIL FKD

zpět na seznam

Použití : Contact Facades - Internal Insulation - Walls

Technický list : EN_fkd.pdf

image (files/ki_cz/upload/FKD_1.jpg)

Description

slab is made from mineral wool. It is hygrophobic throughout its cross section.

USE

NOBASIL FKD slab is intended for thermal, acoustic and fireproof insulation of façade and structural walls, from the outside, by direct attachment followed by coating with plaster.

iconNOBASIL FKD slab

  • it has low thermal conductivity – excellent insulation properties
  • it is non-combustible – it increases the passive safety of buildings
  • it has acoustic properties – it absorbs impact sound energy
  • it has a low vapour diffusion resistance factor - air permeable
  • it is biologically stable – on correct application it maintains long-lasting insulation properties
  • it is resistant to microorganisms and rodents
  • it is chemically neutral – it does not react with surrounding materials under changing temperatures
  • it is stable in volume and shape it is distinguished by high tensile strength (splitting),
  • it is static load-bearing, anchored by a system of adhesive and mechanical anchoring components
  • it is made to very precise dimensions, thanks to which it is possible to attach the slabs to the façade so that they fit together perfectly
  • it is easy to cut to the required size and shape
  • it does not absorb water – hygrophobic throughout its cross section
  • during transport, storage and installation it must be protected from the effects of the weather

Slab NOBASIL FKD is suitable in terms of hygiene.

 

Product dimensions


Thickness

Weight

Lenght

*20 - 160 mm

500 mm, 600 mm

1000 mm

 

Other sizes:

  • (Non-standard sizes can be arranged with the manufacturer.)

Packaging:

  • The appropriate number of slabs are stacked in the form of a bale, which is shrink-wrapped in PE film. Other packaging methods can be arranged with the manufacturer.

Product data


Thickness
(mm)
Width
(mm)
Lenght
(mm)
m2/
pack
λD
(W.m-1.K-1)
RD (m2.K/W)
FKD 2060010007,2max. 0,039 0,5

3060010004,8max. 0,039 0,75

4060010003,6max. 0,039 1

5060010003max. 0,039 1,25

6060010002,4max. 0,039 1,5

7060010001,8max. 0,039 1,75

8060010001,8max. 0,039 2,05

10060010001,2max. 0,039 2,55

12060010001,2max. 0,039 3,05

14060010001,2max. 0,039 3,55

16060010000,6max. 0,039 4,1

Možnosti


Nejnovější zprávy


image (files/ki_cz/upload/sustainability-report_2011.png)

Dramatické události v Japonsku a na Středním Východě během posledních dvanácti ...



image (files/ki_cz/upload/ki-easy_compilation_produkty.png)

Podle průzkumu mezi zájemci o zateplování svépomocí vede cesta zákazníka ...



image (files/ki_cz/upload/rmw-new2011.png)

Kvalita, která se neskrývá - od 19. srpna 2011 společnost Knauf Insulation začíná ...



image (files/ki_cz/upload/sustanability-report-2010_title.PNG)

Svět pravděpodobně již dosáhl vrcholu v těžbě a produkci fosilních paliv. ...


Calc CAD detaily Výrobky KI v SVT

Podporujeme